Chinese Journal of Medical Instrumentation ; (6): 132-135, 2019.
Article in Chinese | WPRIM | ID: wpr-772545

ABSTRACT

The work explored the DEHP migration parameters in PVC infusion in clinic,based on the previous research on the test model of DEHP migrated from PVC infusion,to assess the safety of PVC infusion.The leaching solution samples in different conditions were evaluated by analysis of the DEHP in leaching solution using GC-MS under simulated clinical transfusion way.The release behavior of DEHP was significantly affected by the storage time,storage temperature,surrounding temperature,dripping speed,sterilization process,volume of the leaching solution,and the property of the leaching solution.


Subject(s)
Diethylhexyl Phthalate , Pharmacokinetics , Gas Chromatography-Mass Spectrometry , Plasticizers , Pharmacokinetics , Polyvinyl Chloride , Pharmacokinetics , Temperature
2.
Chinese Journal of Medical Instrumentation ; (6): 458-460, 2014.
Article in Chinese | WPRIM | ID: wpr-310295

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the biuret reagent to detect proteins in the application, the impact of different test conditions for test results.</p><p><b>METHODS</b>The biuret method to select three different instruments, reagents, calibrators are arranged in combination to form 27 sets of detection systems, each detection system is a combination of 5 serum samples for testing, 5 measured values obtained, the selection process normality good a serum for the study to determine the mean value of all AST after culling outliers obtained in order to calculate the various detection systems use a combination of biuret reagent to detect proteins bias.</p><p><b>RESULTS</b>The use of different detection equipment to detect proteins biuret reagent bias, homogeneity of variance (P = 0.467), the difference was not statistically significant (F = 1.688, P = 0.421). different detection reagents using biuret reagent to detect proteins bias, homogeneity of variance (P = 0.574), a statistically significant difference (F = 5.784, P = 0.011). different calibrators use biuret reagent to detect proteins bias, homogeneity of variance (P = 0.467), the difference was statistically significant (F = 5.289, P = 0.000).</p><p><b>CONCLUSION</b>Biuret reagent in the detection of protein applications, impact detection reagents and calibrators will test result, during the test than when it is necessary to detect deviation detection reagents and calibrators due to be considered.</p>


Subject(s)
Biuret , Chemistry , Blood Proteins , Calibration , Indicators and Reagents , Chemistry